Model | Article number | Description |
Unique AutoPure100-L1 | 04-04-002-100 | *Piston Pump Piston pump, metering type FlowRate:0.001-100.000ml/min, Pressure:0-10MPa, Including:2ml Mixer *Auto Inject valve Load,Inject,Waste, 1ml Sample Loop *280nm Fix Wavelength Detector LED Lamp, Life >8000Hr Optical path length :2mm *Conductivity : Range:0.01-999.99(mS/cm) Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm) *Inlet filter kit (2set) *Column holder 1pc *Unique CDSystem chromatography software(Without Computer) |
Unique AutoPure100-L2 | 04-04-002-120 | *Piston Pump Piston pump, metering type FlowRate:0.001-100.000ml/min, Pressure:0-10MPa, Including:2ml Mixer *Auto Inject valve Load,Inject,Waste, 1ml Sample Loop *280nm & 260nm Two Fix Wavelength Detector LED Lamp, Life >2000Hr Optical path length :2mm *Conductivity : Range:0.01-999.99(mS/cm) Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm) *Inlet filter kit (2set) *Column holder 1pc *Unique CDSystem chromatography software(Without Computer) |
Unique AutoPure100-M402 | 04-04-002-102 | *Piston Pump Piston pump, metering type FlowRate:0.001-100.000ml/min, Pressure:0-10MPa, Including:2ml Mixer *Auto Inject valve Load,Inject,Waste, 1ml Sample Loop *DAD402 UV Detector 200-400nm,2 simultaneous wavelengths Optical path length :2mm *Conductivity : Range:0.01-999.99(mS/cm) Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm) *Inlet filter kit (2set) *Column holder 1pc *Unique CDSystem chromatography software(Without Computer) |
Unique AutoPure100-M604 | 04-04-002-164 | *Piston Pump Piston pump, metering type FlowRate:0.001-100.000ml/min, Pressure:0-10MPa, Including:2ml Mixer *Auto Inject valve Load,Inject,Waste, 1ml Sample Loop *DAD604 UV Detector 200-600nm,DAD Detector,4 simultaneous wavelengths Optical path length :2mm *Conductivity : Range:0.01-999.99(mS/cm) Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm) *Inlet filter kit (2set) *Column holder 1pc *Unique CDSystem chromatography software(Without Computer) |
Unique AutoPure100-M804 | 04-04-002-184 | *Piston Pump Piston pump, metering type FlowRate:0.001-100.000ml/min, Pressure:0-10MPa, Including:2ml Mixer *Auto Inject valve Load,Inject,Waste, 1ml Sample Loop *DAD804 UV Detector 200-800nm,DAD Detector,4 simultaneous wavelengths Optical path length :2mm *Conductivity : Range:0.01-999.99(mS/cm) Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm) *Inlet filter kit (2set) *Column holder 1pc *Unique CDSystem chromatography software(Without Computer) |
Model | Article number | Description |
Frac-01S | 03-09-001-006 | Fraction Collector,1Rack |
Frac-02S | 03-09-001-007 | Fraction Collector,2Racks |
OV-02 | 03-15-001-001 | Outlet valves,2 Outlet (waste,1 Frac) |
OV-10 | 03-15-001-003 | Outlet valves,9Outlet(waste,8 fracs) |
CPV02RX | 03-14-001-002 | Column Position Valve ,1 column,Up Flow/Down Flow/Bypass |
CPV03RX | 03-14-001-005 | Column Position Valve ,3 columns,Up Flow/Down Flow/Bypass |
AirS01 | 03-04-006-002 | Bubble sensor,for 1/16tubing |
AirS01-H | 03-18-006-003 | Bubble sensor,for 1/8tubing |
MSV02A-HS | 03-17-001-008 | Inlet valves,2 Inlets (A1,A2),1/8 OD tubing |
MSV02B-HS | 03-17-001-009 | Inlet valves,2 Inlets (B1,B2),1/8 OD tubing |
MSV04-HS | 03-17-001-004 | Inlet valves,4 Inlets (A1,A2,B1,B2),1/8 OD tubing |
MSV10-HS | 03-17-001-007 | Inlet valves,9 inlets,1/8 OD tubing |
DF2 | 03-03-001-008 | 2 Fixed Wavelengths,280nm & 260nm |
DAD402 | 03-03-001-001 | 200-400nm,DAD Detector,2 simultaneous wavelengths |
DAD604 | 03-03-001-003 | 200-600nm,DAD Detector,4 simultaneous wavelengths |
DAD804 | 03-03-001-004 | 200-800nm,DAD Detector,4 simultaneous wavelengths |
pH014 | 03-03-003-001 | pH Detector ,0-14,± 0.1 pH unit within pH 2 to 12 |
SP100 | 03-02-003-001 | SamplePump FlowRate:0.01-100ml/min Pressure:0-10MPa, |
SIV02-HS | 03-17-001-011 | SampleInletValve:1 Sample Inlet,1 buffer,1/8 OD Tubing |
SIV09-HS | 03-17-001-012 | SampleInletValve:8 Sample Inlets,1 buffer,1/8 OD Tubing |
PCP01 | 03-18-002-002 | Pre-Column Pressure Monitor |
PCP02 | 03-18-002-001 | Pre-Column and Post-Column Pressure Monitor |