• Inscinstech Protein Purification System (Unique AutoPure100-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure100-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure100-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure100-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure100-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP

Inscinstech Protein Purification System (Unique AutoPure100-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP

After-sales Service: 1 Year
Warranty: 1 Year
Appliance: Biochemistry
Detector: Dad
Certification: CE
Mobile Phase: Liquid
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Unique AutoPure100-M402
Chromatography Type
Liquid Chromatography
Transport Package
Flight Case
Trademark
Inscinstech
Origin
Suzhou

Product Description

  • Unique AutoPure is a flexible and intuitive chromatography system for the purification of microgram to gram levels of proteins, peptides, nucleic acids, polysaccharides and other target substances.
  • Unique CDSystem chromatography workstation is a powerful, advanced and highly stable chromatography data management system that integrates instrument control, method management, data analysis, standard curve, report editing, user rights management, audit trail, digital signature, Network database and other functions. Comply with FDA 21CFR Part11/GLP/GMP related regulatory requirements.
  • Unique AutoPure selects the core components of well-known European and American manufacturers, with stable performance and high precision; the components in contact with the sample are all biologically inert materials with good biological compatibility.

AutoPure100 series:

Model Article number Description
Unique AutoPure100-L1 04-04-002-100 *Piston Pump
    Piston pump, metering type
    FlowRate:0.001-100.000ml/min,
    Pressure:0-10MPa,
    Including:2ml Mixer
*Auto Inject valve
  Load,Inject,Waste, 1ml Sample Loop
*280nm Fix Wavelength Detector
    LED Lamp, Life >8000Hr
    Optical path length :2mm
*Conductivity :
  Range:0.01-999.99(mS/cm)
  Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm)
*Inlet filter kit (2set)
*Column holder 1pc
*Unique CDSystem chromatography software(Without Computer)
Unique AutoPure100-L2 04-04-002-120 *Piston Pump
    Piston pump, metering type
    FlowRate:0.001-100.000ml/min,
    Pressure:0-10MPa,
    Including:2ml Mixer
*Auto Inject valve
  Load,Inject,Waste, 1ml Sample Loop
*280nm & 260nm Two Fix Wavelength Detector
    LED Lamp, Life >2000Hr
    Optical path length :2mm
*Conductivity :
  Range:0.01-999.99(mS/cm)
  Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm)
*Inlet filter kit (2set)
*Column holder 1pc
*Unique CDSystem chromatography software(Without Computer)
Unique AutoPure100-M402 04-04-002-102 *Piston Pump
    Piston pump, metering type
    FlowRate:0.001-100.000ml/min,
    Pressure:0-10MPa,
    Including:2ml Mixer
*Auto Inject valve
  Load,Inject,Waste, 1ml Sample Loop
*DAD402 UV Detector
    200-400nm,2 simultaneous wavelengths
    Optical path length :2mm
*Conductivity :
  Range:0.01-999.99(mS/cm)
  Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm)
*Inlet filter kit (2set)
*Column holder 1pc
*Unique CDSystem chromatography software(Without Computer)
Unique AutoPure100-M604 04-04-002-164 *Piston Pump
    Piston pump, metering type
    FlowRate:0.001-100.000ml/min,
    Pressure:0-10MPa,
    Including:2ml Mixer
*Auto Inject valve
  Load,Inject,Waste, 1ml Sample Loop
*DAD604 UV Detector
    200-600nm,DAD Detector,4 simultaneous wavelengths
    Optical path length :2mm
*Conductivity :
  Range:0.01-999.99(mS/cm)
  Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm)
*Inlet filter kit (2set)
*Column holder 1pc
*Unique CDSystem chromatography software(Without Computer)
Unique AutoPure100-M804 04-04-002-184 *Piston Pump
    Piston pump, metering type
    FlowRate:0.001-100.000ml/min,
    Pressure:0-10MPa,
    Including:2ml Mixer
*Auto Inject valve
  Load,Inject,Waste, 1ml Sample Loop
*DAD804 UV Detector
    200-800nm,DAD Detector,4 simultaneous wavelengths
    Optical path length :2mm
*Conductivity :
  Range:0.01-999.99(mS/cm)
  Accuracy :± 0.02 mS/cm or ± 2%, whichever is greater (within 0.3 to 300 mS/cm)
*Inlet filter kit (2set)
*Column holder 1pc
*Unique CDSystem chromatography software(Without Computer)

Optional configuration:

Model Article number Description
Frac-01S 03-09-001-006 Fraction Collector,1Rack
Frac-02S 03-09-001-007 Fraction Collector,2Racks
OV-02 03-15-001-001 Outlet valves,2 Outlet (waste,1 Frac)
OV-10 03-15-001-003 Outlet valves,9Outlet(waste,8 fracs)
CPV02RX 03-14-001-002 Column Position Valve ,1 column,Up Flow/Down Flow/Bypass
CPV03RX 03-14-001-005 Column Position Valve ,3 columns,Up Flow/Down Flow/Bypass
AirS01 03-04-006-002 Bubble sensor,for 1/16tubing
AirS01-H 03-18-006-003 Bubble sensor,for 1/8tubing
MSV02A-HS 03-17-001-008 Inlet valves,2 Inlets (A1,A2),1/8 OD tubing
MSV02B-HS 03-17-001-009 Inlet valves,2 Inlets (B1,B2),1/8 OD tubing
MSV04-HS 03-17-001-004 Inlet valves,4 Inlets (A1,A2,B1,B2),1/8 OD tubing
MSV10-HS 03-17-001-007 Inlet valves,9 inlets,1/8 OD tubing
DF2 03-03-001-008 2 Fixed Wavelengths,280nm & 260nm
DAD402 03-03-001-001 200-400nm,DAD Detector,2 simultaneous wavelengths 
DAD604 03-03-001-003 200-600nm,DAD Detector,4 simultaneous wavelengths 
DAD804 03-03-001-004 200-800nm,DAD Detector,4 simultaneous wavelengths 
pH014 03-03-003-001 pH Detector ,0-14,± 0.1 pH unit within pH 2 to 12
SP100 03-02-003-001 SamplePump
FlowRate:0.01-100ml/min
Pressure:0-10MPa,
SIV02-HS 03-17-001-011 SampleInletValve:1 Sample Inlet,1 buffer,1/8 OD Tubing
SIV09-HS 03-17-001-012 SampleInletValve:8 Sample Inlets,1 buffer,1/8 OD Tubing
PCP01 03-18-002-002 Pre-Column Pressure Monitor
PCP02 03-18-002-001 Pre-Column and Post-Column Pressure Monitor







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
104
Year of Establishment
2017-01-09