Inscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Manufacturer/Factory
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
104
Year of Establishment
2017-01-09
  • Inscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
Find Similar Products

Basic Info.

Model NO.
Unique AutoPure100-M804
Appliance
Biochemistry
Detector
Dad
Certification
CE
Mobile Phase
Liquid
Chromatography Type
Liquid Chromatography
Transport Package
Flight Case
Trademark
Inscinstech
Origin
Suzhou

Product Description

Inscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMPInscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
Model Unique AutoPure100-L1
Article No. 04-004- 002-100
Description
1.Piston Pump
1.1 Binary gradient biological inert infusion pump
*Flowrate:
Range: 0.001-100.000ml/min
Flowrate accuracy: 1.2%
Flowrate precision: 0.5%
*Pressure: 0-10MPa
*Dynamic mixer: 2ml, panel mounted, easy to replace
2. Automatic Sampling Valve
2.1 Automatic sampling valve, which can be reversely controlled
by software and supports Load/Inject/Waste
2.2 1ml loop
3. 280nm Fixed Wavelength Detector
3.1 280 nm imported LED detector, life: >8000 Hr
3.2 Noise: ±2×10-5AU
3.3 2mm flow cell
4. Conductivity Detector
4.1 Range: 0.000-999.99 mS/cm
4.2 Accuracy: ±0.02mS/cm or ±2%
5. Chromatography Workstation
(including branded computer, software and communication mod
ule, chromatography workstation software)

 
Model Unique AutoPure100-M402
Article No. 04-004- 002-102
Description
1.Piston Pump
1.1 Binary gradient biological inert infusion pump
*Flowrate: range: 0.001-100.000ml/min
Flowrate accuracy: 1.2%
Flowrate precision: 0.5%
*Pressure: 0-10MPa
*Dynamic mixer: 2ml, panel mounted, easy to replace
2. Automatic Sampling Valve
2.1 Automatic sampling valve, which can be reversely controlled
by software and supports Load/Inject/Waste
2.2 1ml loop
3. DAD Detector
3.1 200-400nm import dual-channel DAD detector
3.2 Noise: ±1×10-4AU
3.3 2mm flow cell
4. Conductivity Detector
4.1 Range: 0.001-999.99 mS/cm
4.2 Accuracy: ±0.02mS/cm or ±2%
5. Chromatography Workstation 
(including branded computer, software and communication mod
ule, chromatography workstation software)

 
Inscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMPInscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMPInscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMPInscinstech Protein Purification System (Unique AutoPure100-M804) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed