• Inscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
  • Inscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP

Inscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP

After-sales Service: 1 Year
Warranty: 1 Year
Appliance: Biochemistry
Detector: Dad
Certification: CE
Mobile Phase: Liquid
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Unique AutoPure300-M402
Chromatography Type
Liquid Chromatography
Infusion Pump
Dual Pump System
Velocity Range
0.01-300ml/Min
Flow Accuracy
±2%
Back Pressure Valve Module
20-200psi Adjustable, Biocompatible
in-Line Filter Module
20um Titanium Alloy Filter
Dynamic Mixer Module
2ml Mixing Chamber
Transport Package
Flight Case
Trademark
Inscinstech

Product Description

Inscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMPInscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP
Model Unique AutoPure300-M402
Article No. 04-004 -002-302
Description
1.Piston Pump
1.1 Binary gradient biological inert infusion pump
*Flowrate:
Range: 0.01-300.000ml/min
Flowrate accuracy: 2%
Flowrate precision: 0.5%
* Pressure: 0-500Psi
*Dynamic mixer: 5ml, panel mounted, easy to replace.
2. Automatic Sampling Valve 
2.1 Automatic sampling valve, which can be reversely controlled
by software and supports Load/Inject/Waste
2.2 5ml loop
3. DAD Detector 
3.1 200-400nm import dual-channel DAD detector
3.2 Noise: ±1×10-4AU
3.3 2mm flow cell
4. Conductivity Detector 
4.1 Range: 0.001-999.99 mS/cm
4.2 Accuracy: ±0.02mS/cm or ±2%
5. Chromatography Workstation
(including branded computer, software and communication
module, chromatography workstation software)

 
Inscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMPInscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMPInscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMPInscinstech Protein Purification System (Unique AutoPure300-M402) Fplc Can Meet The Requirements of FDA 21 CFR Part 11/GLP/GMP

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
104
Year of Establishment
2017-01-09